We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Your position: Home / Transmitter Custom / Differential Pressure Transmitter

JC30 Air Pressure / Micro Differential Pressure Transmitter

JC30
Pressure Range:0-1Kpa
Accuracy:0.5%FS
Pressure Connector:M20X1.5 male thread
Output:0-5VDC
Power Supply:24VDC
Different specificaiton with different price
Price:
$150.00
  • Quantity:
    1-50pc
    51-200pc
  • Male Thread Size:
    M20X1.5
    G1/4
    NPT1/4
Quantity:
-
+
(2000 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
Please select the information you wantX
  • Description
  • Dimensions(mm)
  • Electrical Connections
  • Technical Parameters
  • Ordering Information
  • Reviews



Introduction

JC30 is an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance. It is rugged and durable to meet the requirements of more stringent industrial standards. It is widely used in industrial support, industry support and equipment support. The series includes a variety of options, which are applied to different industries and different working conditions. It solves the needs for economic pressure monitoring in different occasions and serves a wide range of industries.
JC30 air pressure / micro differential pressure transmitter adopts new technology to produce micro range, high stability silicon piezoresistive non-oil-filled sensor components and special digital integrated circuits. It is firmly packaged with 304 stainless steel casing through stress isolation technology. The measured air pressure or differential pressure enters the positive and negative pressure chamber of the sensor through the G1/4 external thread or φ6 integrated barbed tower pressure interface, and the corresponding air pressure or differential pressure is converted into a plurality of industrial standard signal outputs proportional to the sensor detection, Such as 4 ~ 20mA, 0-5V DC, 0.5-4.5V DC.

Features

* Measuring range: 0~100Pa...100KPa
* All stainless steel construction, compact and durable, easy to install
* Temperature range is -20~100°C
* Wind pressure, differential pressure two kinds of structural interoperability design
* Accuracy 1-2% FS for pressure below 250Pa, accuracy 0.5% of industry standard FS for other ranges
* Reliable quality and cost-effective

Application

* HVAC
* Energy Management System
* VAV and fan control
* Environmental pollution control
* Clean room, clean room project
* Oven pressurization and furnace ventilation control
* Monitoring of natural gas and gas pipeline network
* Downhole ventilation test
* Pharmaceutical equipment and medical equipment
* Filter pressure
* Building exhaust system

Performance Parameter

Measuring Range 0~100Pa...100KPa
Overload Capability 1.5~2 times full-scale pressure
Burst Pressure 4xFS
Durability ﹥1x107 cycle(P:0~FS)
Pressure Type Gauge / Absolute
Measuring medium Dry clean gas compatible with 304 stainless steel
Response time ≤4ms
Resolution Minimum. 0.5Pa 
Accuracy (linear,hysteresis, repeatability) Typical:±0.5%FS Maximum:±1%FS
Typical:±1%FS(below 250Pa) Maximum:±2%FS(below 250Pa)
Long-term stability Typical:±0.2%FS/year Maximum:±0.3%FS/year
Zero temperature drift Typical:±0.02%FS/℃ Maximum:±0.05%FS/℃
Sensitivity temperature drift Typical:±0.02%FS/℃ Maximum:±0.05%FS/℃

Environmental Conditions

Medium Temperature -40~100℃ 
Ambient Temperature -40~85℃
Compensation Temperature -20~80℃  
Vibration resistance 10g                 IEC 60068-2-6
Impact resistance 100g/1ms       IEC 60068-2-27
EMC- launch EN61000-6-3
EMC- anti-interference EN61000-6-2
Insulation resistance ﹥100MΩ/100V 
Shell Protection Plug type(IP65);  Cable type(IP67)   Compliance IEC 60529 standard
Certification CE

Electrical Specifications

Code Standard signal(with 
short circuit protection)
Supply voltage with
polarity protection
Power supply-Current Load(R) Output Impendence
A1 4~20mA  DC 9~30V Max.25mA R≤(U-9)/0.02Ω  
V1 1~5V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V2 0~5 V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V3 0.5~4.5V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V4 0.5~4.5V DC DC 5±0.25V 8mA R≥50kΩ <2kΩ

Material 

Interface and housing Stainless Steel 304L
O-ring Silicone Rubber
Sensor Diaphragm Silicon wafer(measured dry ,dust-free, non-corrosive or weakly corrosive, clean gas)
Weight Approx.150g
JC30 G 01KN A1 F2 W2
Model Pressure type Pressure Range Output Mounting thread Electrical connections
JC30 G=Gauge or wind/
air pressure 
D=Differential Pressure
002C= ±200Pa  G/D
005C= ±500Pa  G/D
01KC= ±1KPa  G/D
02KC= ±2KPa  G/D
05KC= ±5KPa  G/D
10KC= ±10KPa G/D
005N= -500Pa  G/D
01KN= -1KPa  G/D
02KN= -2KPa  G/D
05KN= -5KPa  G/D
10KN= -10KPa  G/D
20KN= -20KPa  G/D 
002P= 200Pa  G/D
005P= 500Pa  G/D
01KP=1KPa  G/D
02KP= 2KPa  G/D
05KP= 5KPa  G/D
10KP= 10KPa  G/D
20KP= 20KPa  G/D
40KP= 40KPa  G/D
001B= 100KPa  G/D
A1=4~20mA
V1=1~5V 
V2=0~5V  
V3=0.5~4.5V 
V4=0.5~4.5V/5V
F1=M20x1.5male 
F2=G1/4male
F5=Ф8 gas nozzle
F0= Customize
W1=Straight Out 1m
W2=A type HSM plug 
W3=M12 corner out 1m
W4=M12 Straight Out 1m

Model example: JC30G01KNA1F2W3
(JC30 Air Pressure/ Micro Differential Pressure Transmitter; Range 0~1MPa Gauge; Output 4~20mA; Accuracy 0.5% typical; Power Supply 9~30VDC;Pressure Connection G1/4 male thread; Electrical Connection M12 corner out 1m;  Selection Remarks: The range meter 01KP=1KPa G/D G indicates the gauge pressure or wind/air pressure, which is the pressure difference with the atmosphere, that is, the wind pressure measurement of a single pressure port, D is the differential pressure measurement, measuring the pressure difference between the two pressure ports. Use the B-copper joint in the outline drawing to connect the negative pressure port, as shown in the outline drawing.
Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the sales engineers for details.
Average rating:
Share your thoughts with other customers
Write a review
Product reviews can be carried out after the member login, please click here to login