We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Your position: Home / Transmitter Custom / Pressure Transmitter

JC101 Diffusion Silicon Temperature and Pressure Integrated Sensor / Transmitter

JC101
Measuring Range:0~40KPa...7MPa
Accuracy:0.5%FS
Pressure Connector:M20X1.5 male thread
Output:4-20mA
Power Supply:24VDC
Different specificaiton with different price
Price:
$150.00
Quantity:
-
+
(1000 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
Please select the information you wantX
  • Description
  • Dimensions(mm)
  • Electrical Connections
  • Technical Parameters
  • Ordering Information
  • Reviews



Introduction

JC series is an industrial measuring instrument product that is designed as a modular design that complies with OEM standards. Stable and reliable quality, high cost performance, and it is rugged enough to meet more stringent industrial standard requirements. Widely used in industry supporting ,equipment supporting, different industries and different working conditions. It solves the needs of economic pressure monitoring in different occasions and serves a wide range of industries.
JC101 diffused silicon temperature and pressure integrated sensor / transmitter uses a silicon piezoresistive oil-filled core and a high-precision PT100 platinum resistor is embedded in the core base. The thermally conductive adhesive is potted in the gap between the platinum resistor and the stainless steel shell, which greatly reduces the hysteresis of temperature conduction without the platinum resistor in direct contact with the medium. Temperature and pressure are the most widely measured parameters. The integrated temperature and pressure sensor saves installation time, space and cost for many industrial occasions and equipment. The special digital integrated circuit inside the transmitter converts the millivolt signal of the sensor into standard voltage and current signals (such as 4-20mA, 0-5VDC, 0.5-4.5VDC), etc., which can be collected by the acquisition card and computer or directly with the control instrument, Smart meters, PLCs, etc. are connected; I2C digital signals, only need battery DC 3.3 ~ 5V power supply, low power consumption can meet the low power pressure measurement of various wireless meters. This series has the characteristics of small size, light weight, easy and simple installation, etc., all stainless steel sealed structure, can work in corrosive environments, and has very good vibration and shock resistance.

Features

* Built-in PT100 temperature sensor
* Measuring range: 0 ~ 40KPa …… 70bar
* 0.5% FS (typical) accuracy of industry standard
* Diffuse silicon sensitive , strong anti-interference, good long-term stability
* Adopt international standard anti-damping design, can resist 300% instant impact
* Compact structure, integrated temperature and pressure, stable and reliable quality, high cost performance
* 316L stainless steel isolation corrugated diaphragm can measure gas, liquid, gas-liquid mixture and other fluid
* Various industrial signal output 4 ~ 20mA, DC 0 ~ 5V, DC 1 ~ 5V , DC 0.5 ~ 4.5V, I2C and  PT100

Application

* Hydraulic and pneumatic fields
* Measurement and control technology
* Machinery manufacturing, equipment matching, pumps and compressors
* Temperature and pressure measurement of gas and liquid in various fields
* Liquid level, volume or mass measurement and temperature measurement
* Can be integrated into various user-defined temperature and pressure integrated solutions
* Smart water, smart gas, smart fire, air-conditioning and refrigeration, automotive electronics

Selection Code S-pulse Buffer Media Status and Application

JC10 Diffused Silicon Pressure Transmitter Application
Cavitation, liquid hammer, and peak pressure may occur in the hydraulic system, such as when the value is quickly closed or the pump is turned on and off. Such problems may occur at the inlet and outlet ends, even if the operating pressure is extremely low.
Media Status
The inclusion of particulate matter in the liquid may cause nozzle clogging. Mounting the sensor in a vertical position minimizes the risk of nozzle clogging, as the nozzle can only contact the liquid after the inactive volume of the nozzle orifice is filled with liquid at startup. The influence of the viscosity of the medium on the response time is very small. Even if the viscosity is as high as 100cSt, the response time will not exceed 5ms.

Performance Parameter

Measuring Range 0~40KPa...7MPa   Pressure
-40~125℃            Temperature
Overload Capability 1.5~2 times full-scale pressure (with damping can resist 300% instantaneous impact)
Burst Pressure 4xFS (≤20MPa)
Durability ﹥1x107 7cycle(P:10~90%FS)
Pressure Type Gauge / Absolute
Measuring medium Gas or liquid compatible with 316 stainless steel
Response time ≤4ms pressure
Resolution 0.01%FS
Accuracy (linear,hysteresis, repeatability) Typical:±0.5%FS Maximum:±1%FS
Long-term stability Typical:±0.2%FS/year Maximum:±0.3%FS/year
Zero temperature drift Typical:±0.02%FS/℃ Maximum:±0.04%FS/℃
Sensitivity temperature drift Typical:±0.02%FS/℃ Maximum:±0.04%FS/℃

Environmental Conditions

Medium Temperature -20~85℃ 
Ambient Temperature -20~85℃
Compensation Temperature -10~60℃  
Vibration resistance 20g                 IEC 60068-2-6
Impact resistance 500g/1ms       IEC 60068-2-27
EMC- launch EN61000-6-3
EMC-anti-interference EN61000-6-2
Insulation resistance ﹥100MΩ   500V AC-1min
Shell Protection Plug type(IP65);Cable type(IP67)   Compliance IEC 60529 standard
Certification CE

Electrical Specifications

Code Standard signal
(with short
circuit protection)
Supply voltage with
polarity protection
Power supply-Current Load(R) Output Impendence
A1 4~20mA +PT100 DC 9~30V ≤25mA R≤(U-9)/0.02Ω  
V1 1~5V DC+PT100 DC 9~30V 8mA R≥50kΩ <2kΩ
V2 0~5 V DC+PT100 DC 9~30V 8mA R≥50kΩ <2kΩ
V3 0.5~4.5V DC+PT100 DC 9~30V 8mA R≥50kΩ <2kΩ
V0 mV+PT100 DC 1.5mA 1.5mA    
S3 I2C DC 3.3~5V <1mA    

Material 

Interface and housing Stainless Steel 304L
O-ring Fluororubber
Sensor Diaphragm Stainless Steel 316L
Weight Approx.150g
JC101 G 10B A1 F2 W2 S
Model Pressure type Pressure Range Output Mounting thread Electrical connections Buffer
JC101 G=Gauge
A=Absolute
040K =40KPa G
100K=100KPa G/A
160K=160KPa G/A
04B=4bar G/A
06B=6bar G/A
10B=10bar G/A
16B=16bar G/A
25B=25bar G/A
40B=40bar G/A
70B=70bar G/A
A1=4~20mA+PT100
V1=1~5V +PT100
V2=0~5V +PT100
V3=0.5~4.5V +PT100
V0=mV+PT100
S3=I2C+PT100
F1=M20x1.5male
F2=G1/4 male
F3=1/4NPT
F0= Customize
W1= Straight Out 1m
W2= Aviation plug 1 m
W3= M12 corner out 1m 
W4=M12 Straight Out 1m
S= With buffer Default is without buffer
T= =Special

Model example: JC101G10BA1F2W1S
(JC101 Diffusion Silicon Temperature and Pressure Integrated Sensor/Transmitter;Range:0-1MPa Gauge;Output:4-20mA+PT100;Accuracy: 0.5%FS typical;Power Supply:9~30V DC, ;Pressure Connection:G1/4 male;Electrical Connection:straight out ;with buffer,,Special instruction:010B=10bar G/A, G/A stands for gauge and absolute pressure, G gauge, A absolute) 
Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the sales engineers for details.
Average rating:
Share your thoughts with other customers
Write a review
Product reviews can be carried out after the member login, please click here to login