Introduction
JC-CT02 encapsulates the diffusion silicon pressure sensitive chip into the 316L stainless steel casing, and the applied pressure is transmitted to the sensitive chip through the stainless steel diaphragm and the inner sealed silicone oil. The sensitive chip does not directly contact the measured medium to form an all-solid structure of pressure measurement. Therefore, the product can be applied to various occasions. The product has a small range medium compatibility of at least 7KPa, and the vacuum measurement range is comprehensive.
Features
* Dia.19mm
* 0~100mV output
* Gauge, absolute, vacuum
* Temperature compensated
Application
* Medical Instruments
* Process Control
* Fresh & Waste Water Measurements
* Refrigeration/Compressors
* Pressure Transmitters
* Hydraulic Controls
Parameters |
≤34KPa |
≥100KPa |
MIN |
TYP |
MAX |
MIN |
TYP |
MAX |
Span mV |
50 |
100 |
150 |
75 |
100 |
150 |
Zero pressure output mV |
-2 |
0 |
2 |
-1 |
0 |
1 |
Non-linearity %Span |
7KPa: -0.30 to 0.30 |
-0.1 |
|
0.1 |
34KPa: -0.20 to 0.20 |
-0.2 |
|
0.2 |
Hysteresis %Span |
-0.1 |
±0.02 |
0.1 |
-0.05 |
±0.02 |
0.05 |
Repeatability %Span |
|
±0.02 |
|
|
±0.02 |
|
Input Resistance KΩ |
2 |
3.5 |
6.5 |
2 |
3.5 |
5.8 |
Output Resistance KΩ |
4 |
|
7 |
4 |
|
6 |
Temperature Error-Span %Span |
-1 |
|
1 |
-0.75 |
|
0.75 |
Temperature Error-Offset %Span |
-1 |
|
1 |
15psi: -0.75 to 0.75; >15psi: -0.50 to 0.50 |
Thermal Hysteresis-Span %Span |
-0.25 |
±0.05 |
0.25 |
-0.25 |
±0.05 |
0.25 |
Thermal Hysteresis-Offset %Span |
-0.25 |
±0.05 |
0.25 |
-0.25 |
±0.05 |
0.25 |
Long-term stability-Span %/year |
|
±0.1 |
|
|
±0.1 |
|
Long-term stability-zero % /year |
|
±0.25 |
|
|
±0.25 |
|
Supply Current mA |
0.5 |
1.5 |
2 |
0.5 |
1.5 |
2 |
Output Load Resistance MΩ |
5 |
|
|
5 |
|
|
Insulation Resistance MΩ (50VDC) |
50 |
|
|
50 |
|
|
Output Noise uV p-p (10Hz to 1KHz) |
|
1 |
|
|
1 |
|
Response Time ms (10% to 90%) |
|
0.1 |
|
|
0.1 |
|
Pressure Overload Rated |
7kpa: 10X max; 34kpa: 3X max |
|
|
3X |
Pressure Burst Rated |
7kpa: 12X max; 34kpa: 4X max |
|
|
4X |
Compensated temperature °C |
7kpa: 0 to 50; 34kpa: 0 to 70 |
-20 |
|
85 |
Operating temperature °C |
-20 |
|
70 |
|
|
125 |
Storage Temperature °C |
-50 |
|
125 |
|
|
125 |
Media – Pressure Port |
Liquids and Gases compatible with 304/316L Stainless Steel |
Media – Reference Port |
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber, and 304/316L Stainless Steel |
JC-CT02 Pressure sensor |
Model |
Description |
JC-CT02 |
Diameter 19mm O Ring mounting |
|
Code |
Power Supply |
C |
Constant Current |
V |
Constant Voltage |
|
Code |
Pressure Range |
Gauge |
Absolute |
7K |
0~7KPa |
* |
|
30K |
0~30KPa |
* |
* |
100K |
0~100KPa |
* |
* |
200K |
0~200KPa |
* |
* |
350k |
0~350KPa |
* |
* |
700K |
0~700KPa |
* |
* |
2M |
0~2MPa |
* |
* |
3.5M |
0~3.5MPa |
* |
* |
XX |
Customized |
|
Code |
Pressure type |
G |
Vent Gauge Pressure(W/O vent tube as default) |
A |
Absolute Pressure |
|
Code |
Electrical Connection |
1 |
Connect Pins |
2 |
Ribbon Cable (90mm as default) |
X |
Special |
Note:
1. Least squares fitting straight line
2. Compared with the output of 25 °C in the compensation temperature range
3. Can be used for down-range, and the amplitude is controlled within ±50%FS.
4. The maximum pressure of the system should be less than the overload protection limit of the sensor, otherwise it will affect the service life of the product and damage the product.
5. The commonly used compensation method for products is 1.5mA constant current compensation.
6. Do not force to pull the pins or the leads of sensitive components.
7. Protect the isolation diaphragm at the front end of the pressure sensitive component to prevent the impact of the pressure sensitive component from damaging the sensitive component.
8. If you have special requirements on product performance parameters and functions, please contact us.
Product reviews can be carried out after the member login, please
click here to login