We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Your position: Home / Transmitter Regular / Vacuum Pressure Transmitter

JC627 Vacuum / Absolute Pressure Transmitter

JC62701
Pressure Range:0-100Kpa A
Accuracy:0.5%FS
Pressure Connector:M20X1.5 male thread
Output:4-20mA or 0-5VDC
Power Supply:24VDC
Different specificaiton with different price
Price:
USD
$390.00
$550.00
  • Accuracy:
    0.5%FS
    0.25%FS
    0.1%FS
  • Range:
    0...200pa...2000pa
    0...5KPa..20KPa
    0...50KPa,100kpa...3.5Mpa
Quantity:
-
+
(18000 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
Please select the information you wantX
  • Description
  • Electrical Connections
  • Technical Parameters
  • Ordering Information
  • Reviews



Introduction

As a new series product specially used for vacuum measurement and control, JC627 vacuum / absolute pressure transmitter has completely solved the problem of difficult vacuum measurement. This series product has three specifications, i.e. JC627G negative pressure transmitter, JC627A absolute pressure transmitter and JC627CA capacitor thin-film absolute pressure transmitter, which have widely been used in such fields as pharmaceutical, medical equipment, airspace and aerospace, scientific research, leakage detection and completed automation equipment fields.
By use of a mono-crystalline silicon thick–film sensor, JC627G negative pressure transmitter is equipped with a high-accuracy signal processing circuit, with stable and reliable performance, which has solved such disadvantages of domestic diffused silicon-type negative pressure vacuum products as unstable signal and short service life. Normal ranges include 0 ~ 100KPa and 0 ~ 50KPa, etc..
JC627A absolute pressure transmitter adopts such advanced foreign new high technologies as absolute pressure chips, temperature automatic compensation, and normalized circuit debugging etc., to expand the absolute pressure range to 5KPa at the minimum, and to greatly enhance the overall accuracy of the product. Characterized by advanced technology, superior performance, reliable quality and small volume, this product has quite obvious advantages in high cost performance by comparison with domestic similar absolute pressure products.
JC627CA capacitor thin-membrane absolute pressure transmitter is a vacuum pressure gauge made in China through the introduction of foreign capacitor thin-film gauge technology and internationally advanced calibration equipment. This product works by the capacitance changing principle. Its minimum range may be up to 0.02MPa ~ 200MPa absolute pressure, and its detection won’t be influenced by the type and component of the medium to be detected. Its output of standard electric signals can be remotely transmitted, to facilitate intelligent control of microprocessors. Therefore, it is ideal for the measurement of low vacuum pressure.

Features

* Fully provided with foreign high- accuracy sensing elements, with the maximum accuracy of up to 0.1% FS
* Continuously operable for a long time, with good long- term stability
* Applicable for measuring corrosive medium according to special requirements
* Strong overloading resistibility.Fast response. Stable and reliable performance
* Applicable for hazardous areas, with intrinsically safe explosion-proof type Ex ia II CT5
* With structural diversification, the product can be designed in an individualized manner as per customers’ special requirements
JC627 Vacuum / Absolute Pressure Transmitter
JC627 Vacuum / Absolute Pressure Transmitter
Measuring media The gas or liquid compatible with 316 stainless steel
Pressure type Negative gauge pressure (G)
silicon- type absolute pressure (A)
capacitor thin-film absolute pressure (CA)
Overload capacity 2 times at negative gauge pressure; 10 times to one hundred times at micro-range absolute pressure
Measuring range Negative gauge pressure: 0~-5KPa ..-50KPa…-100KPa
Silicon-type absolute pressure: 0~5KPa…..10KPa …20KPa…100KPa…200KPa…1MPa
Capacitor thin-film absolute pressure: 0.02Pa~200Pa、1Pa~1KPa
Overall accuracy (nonlinearity + repeatability+ hysteresis) ±0.1%FS ±0.25%FS ±0.5%FS
Long-term stability Typical:±0.1%FS/ year Maximum:±0.15%FS/year
Zero temperature drift Typical:±0.01%FS/℃ Maximum:±0.15%FS/℃
Sensitivity temperature drift Typical:±0.01%FS/℃ Maximum:±0.15%FS/℃
Range of operating temperature -20~ 80℃
Range of compensation temperature  -10 ~ 60℃
Ambient temperature -20 ~ 80℃
Range of power supply 12~36VDC(generally 24VDC)
Signal output 4~20mA/1~5VDC/0~5VDC
Load resistance ≤(U-12)/0.02  Ω
Resolution Infinitely small (theoretical),,1/100000(normal)
Enclosure protection class Plug type(IP65); cable type (IP67)
Safety and explosion protection Ex iaⅡ CT5
Vibration error ≤±0.01%FS(Axes X, Y and Z, 200Hz/g)
Response time ≤2 ms
JC627 Vacuum/Absolute Pressure Transmitter
  Pressure type Negative gauge pressure (G),
silicon- type absolute pressure (A),
capacitor thin-film absolute pressure (CA)
  Measuring range 0~X KPa or 0~X Mpa
  Code Overall accuracy (linearity + repeatability+ hysteresis)
1 ±0.5%FS
2 ±0.25%FS
3  ±0.1%FS
  Code  Signal output
A1 4~20mA(12~36V DC)
V1 1~5V DC(12~36V DC)
V2 0~5V DC (12~36V DC)
V3 0~10V DC(24V DC)
  Code Additional functions
F1 M20x1.5  external thread
F2 G1/4 external thread
F3 Clamped type
F0 Special
W1 Cable type (IP67,2m)
W2 Socket type (IP65,DIN43650)
W3 Aviation plug
P Flush-diaphragm type
E Intrinsically safe explosion-proof type Ex iaIICT6
JC627(0~10KPa)—1 —A1 —F1 —W2   Vacuum/Absolute Pressure Transmitter

Tips for Type Selection

1. The medium to be measured shall be compatible with the material contacting with the product.
2. As an additional function code for type selection, the code “E” for intrinsically safe explosion-proof type Ex iaIICT6 denotes that power source must be supplied via safety barrier.
3. For other special requirements, please discuss with us and clearly indicate them in the order.
Average rating:
Share your thoughts with other customers
Write a review
Product reviews can be carried out after the member login, please click here to login