Introduction
For general piezoresistive pressure sensor, the four force-sensing resistors of its sensitive Wheatstone bridge for control and measuring are manufactured using IC technology. The resistors are isolated from one another with PN junction. The highest operating temperature is only 125℃ due to temperature resistant limitation of the PN junction. However, the performance of sensor has greatly been deteriorated after the temperature is above 100℃ because reverse current leakage of the PN junction rises with the exponent of the temperature, which limits the temperature range available for the conventional piezoresistive sensor. Utilization of thick film technology to make force-sensing resistor can expand the operating temperature up to 125℃; utilization of multi-crystalline silicon SOI technology to make force- sensing resistor can expand the operating temperature up to 150℃; utilization of the traditional SOS technology and advanced SOI technology can expand the operating temperature up to 180°C-350°C. Utilization of the latest β–phase high- temperature force -sensing material SiC, combined with SOI technology can expand the operating temperature up to 450℃ ~ 850℃. JC680 high-temperature pressure transmitter / sensor is assembled through strict process using internationally advanced sensor, supported with high-precision electronic elements.
Features
* Stainless steel enclosure, with excellent corrosion resistance
* Wide pressure measuring range
* Wide temperature measuring range, with very small temperature error
* Stable working and strong interference immunity
* High reliability, dual-diaphragm structure
* Small dimensions, light weight, and a variety of types
* Reverse polarity, over-voltage and over-current protection
* Wide range of measured medium
Application
* Chemical
* Water conservancy
* Industrial process control
* Power generation engineering
* Thermal energy engineering
* Petroleum survey and investigation
* Airspace and aerospace
* Scientific research of national defense
Measuring range |
0~10KPa…1MPa…100MPa |
Overload capacity |
Two times FS pressure ((1.1 times FS pressure for 100MPa product) |
Pressure type |
Gauge pressure or absolute pressure or sealed reference pressure |
Measured medium |
Gas or liquid compatible with 316 stainless steel |
Overall accuracy |
±0.25%FS |
±0.5%FS |
±1%FS |
Operating temperature range |
-40°C~+150°C |
-40°C~+200°C |
-40°C~+250°C |
-40°C~+250°C |
Compensation temperature range |
-20°C~+130°C |
-20°C~+180°C |
-20°C~+200°C |
0°C~+250°C |
Long-term stability |
Typical: ±0.1%FS/year |
Maximum: ±0.2%FS/ year |
Zero point temperature drift |
Typical: ±0.02%FS/℃ |
Maximum: ±0.05%FS/℃ |
Sensitivity temperature drift |
Typical: ±0.02%FS/℃ |
Maximum: ±0.05%FS/℃ |
Range of power supply |
12~36VDC(24VDC generally) |
Signal output |
4~20mA / 1~5V DC / 0~5V DC |
Load resistance |
≤(U-12)/0.02 Ω |
Response time |
≤3 ms |
Thermal lagging |
±0.1% (typical) |
Enclosure protection degree |
Plug type (IP65); cable type (IP67) |
Safe explosion-proof |
Ex iaⅡ CT5 |
Vibration error |
≤±0.01%FS(Axes X,Y,Z,200Hz/g) |
Insulation resistance |
100MΩ,500V DC |
JC680 |
High-temperature Pressure Transmitter |
|
Pressure type |
Gauge pressure ( G, may not be indicated); absolute pressure (A) |
|
Range |
Measuring Range (0~ X KPa or MPa) |
|
Code |
Range of operating temperature |
C1 |
-40°C~+150°C |
C2 |
-40°C~+200°C |
C3 |
-40°C~+250°C |
C4 |
-25°C~+350°C |
C5 |
0°C~+800°C (High – temperature, water – cooled) |
|
Code |
Overall accuracy (linearity + repeatability + lagging) |
0 |
±1.0%FS |
1 |
±0.5%FS |
2 |
±0.25%FS |
|
Code |
Signal Output (Standard power supply) |
A1 |
4~20mA (12~36V DC) |
V1 |
1~5V DC (12~36V DC) |
V2 |
0~5V DC(12~36V DC) |
|
Code |
Additional functions |
F1 |
M20x1.5 external thread |
F2 |
G1/4 external thread |
F0 |
Special |
W1 |
Cable type (IP67, 2m) |
W2 |
Socket type (IP65,DIN43650) |
P |
Flush diaphragm |
E |
Intrinsically safe explosion-proof type Ex iaIICT5 |
JC680(0~10MPa)—C1 —1 —A1 —F1 —W1 —E High-temperature Pressure Transmitter |
Tips for Type Selection
1. The measured medium shall be within the product operating temperature range and usage beyond the range shall be avoided.
2. The code E, an additional functional code for selection, namely, intrinsically safe explosion-proof type Ex iaIICT5, must be power supplied via safety barrier.
3. Please contact us for other special requirements and clearly indicate them in the order.
Product reviews can be carried out after the member login, please