We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Your position: Home / Pressure Sensor / Diffusion Silicon Pressure Sensors

JC-CZ15 Oil Filled Sensor Small Profile

JCCZ15
Ø12.6mm oil filled Diffused silicon
Output:100mV(typical)
Compensation Temp. -10~70℃
Pressure Range: 0~100KPa….7MPa
Price:
$35.00
  • Range:
    100KPa
    160KPa
    400KPa
    600KPa
    1MPa
    1.6MPa
    2.5MPa
    4MPa
    7MPa
  • Pressure Type:
    Gauge
    Absolute
  • Power Supply:
    Constant current
    Constant Voltage
  • Thread Size:
    Diameter 12.6mm weldable sensor
    With pressure port
Quantity:
-
+
(10000 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
Please select the information you wantX
  • Description
  • Dimensions(mm)
  • Technical Parameters
  • Ordering Information
  • Reviews



Introduction

JC-CZ15 oil filled sensor are based on piezoresistive silicon pressure sensors packaged in a 316L stainless steel housing. The sensing package utilizes silicon oil to transfer pressure from the 316L diaphragm to the sensing element.
It is a small profile sensor, designed for pressure port welding or o-ring mounting. Each sensor was strictly temperature compensated for both zero and span.
There are two options of excitation power -- current and voltage. We can also provide port welded sensor(JC-CZ17).

Features

* Low cost OEM
* Pressure range:0-100Kpa…7Mpa     
* Wide operable temperature range -40-125℃   
* Compatible with corrosive media     
* Small profile and easily to be welded    
* Typical output:0-100mV

Application

* Process control   
* Fresh and waste water measurements       
* Medical and food instruments    
* Pressure transmitters
JC-CZ15 Oil Filled Sensor

Specifications of current excitation(1.5mA, 25℃)

Parameters Min. Typical Max.
Accuracy(%FS) Non-Linearity1   ±0.10 ±0.20
Hysteresis   ±0.05 ±0.10
Repeatibility   ±0.05 ±0.10
Zero2  Output(mV) -2 ±1 2
Span(FS) Output(mV)   70    
Operation Temp.(℃)3 -40   125
Compensated Temp.(℃)  100Kpa  0   70
Compensated Temp.(℃) ≥100Kpa -10   70
Zero Temp.error(%FS)4   ±0.75 ±1.0
Span Temp. error(%FS)4   ±0.75 ±1.0
Thermal hysteresis(%FS)   0.1  
Long term Stability/Zero (±%FS annual)   0.1  
Long term Stability/Span (±%FS annual)   0.1  
Supply Current(mA) 0.5 1.5 2
Input Resistance(KΩ) 2 2.5 3
Output Resistance(KΩ) 2.5 3 3.7
Load Resistance5(MΩ) 5    
Insulation Resistance(100V)6(MΩ) 100    

Specifications of voltage excitation(10VDC 25℃)

Parameters Min. Typical Max.
Accuracy(%FS) Non-Linearity1   ±0.10 ±0.20
Hysteresis   ±0.05 ±0.10
Repeatibility   ±0.05 ±0.10
Zero2  Output(mV) -2 ±1 2
Span(FS) Output(mV)  < 7MPa 98  100±1 102
Span(FS) Output(mV)   7MPa 147 150±1.5 153
Operation Temp.(℃)3 -40   125
Compensated Temp.(℃) 100KPa 0   70
Compensated Temp.(℃) >100KPa -10   70
Zero Temp.error(%FS)4   ±0.75 ±1.0
Span Temp. error(%FS)4   ±0.75 ±1.0
Thermal hysteresis(%FS)   0.1  
Long term Stability/Zero (±%FS annual)   0.1  
Long term Stability/Span (±%FS annual)   0.1  
Supply Voltage(VDC)   10 14
Input Resistance(KΩ) 6 8 10
Output Resistance(KΩ) 2.5 3 3.7
Load Resistance5(MΩ) 5    
Insulation Resistance(100V)6(MΩ) 100    

Remark
1. Best fit straight line.
2. Measured at vacuum for absolute (A), ambient for gage (G). 
3. Maximum temperature range for product with standard cable is -20°C to +105°C. 
4. Over the compensated temperature range with respect to 25°C. 
5. Load resistance to reduce measurement errors due to output loading.
6. Between case and sensing element
Model Description
JC-CZ15 Diameter 12.6mm weldable sensor
JC-CZ17 With pressure port
  Code Power Supply
C Constant Current
V Constant Voltage
  Code Pressure Range Gauge Absolute
100K 0~100KPa * *
160K 0~160KPa * *
400K 0~400KPa * *
600k 0~600KPa * *
1M 0~1MPa * *
1.6M 01.6MPa * *
2.5M 0~2.5MPa * *
4M 0~4MPa * *
7M 0~7MPa * *
XX Customized
  Code Pressure type
G Vent Gauge Pressure(W/O vent tube as default)
GT Vent Gauge Pressure(With vent tube )
A Absolute Pressure
S Sealed Gauge
  Code Electrical
1 Connect Pins
2 Ribbon Cable(90mm as default)
X Customized
  Code Pressure port(For A17)
1 1/4NP
x Customized

Note: If need to do vacuum test for vent gauge sensor, pls. consulted with factory
1. Can be used for down-range, and the amplitude is controlled within ±50%FS.
2. The maximum pressure of the system should be less than the overload protection limit of the sensor, otherwise it will affect the service life of the product and damage the product.
3. The commonly used compensation method for products is 1.5mA constant current compensation.
4. Do not force to pull the pins or the leads of sensitive components.
5. Protect the isolation diaphragm at the front end of the pressure sensitive component to prevent the impact of the pressure sensitive component from damaging the sensitive component.
6. If you have special requirements on product performance parameters and functions, please contact us.
Average rating:
Share your thoughts with other customers
Write a review
Product reviews can be carried out after the member login, please click here to login